Control Logics
Atos induction systems are designed for seamless integration into both new and existing machinery, offering a choice of three distinct control modes.
Temperature control via proportional command
Temperature control is managed by the EPG generator. The machine control unit provides the EPG generator with a temperature setpoint, either via a 0 – 10 Volt analogue proportional signal corresponding to 0° – 350° C or via Modbus RTU communication.
Power control via proportional command
Power control is managed by the EPG generator, while temperature control is managed by the machine control unit. The machine control unit provides the EPG generator with a power setpoint, either via a 0 – 10 Volts analog proportional signal, corresponding to 0 – 100% of the generator’s nominal power, or via Modbus RTU communication.
Power control via ON-OFF command
Power control is managed by the EPG generator, while temperature control is managed by the machine control unit. The machine control unit provides the EPG generator with an ON-OFF power enable signal. The command can be a dry contact via relay or an ON-OFF 0 – 10 Volt signal.